Mitsubishi low voltage circuit breakers prolong the lifespan of electrical equipment.

For over a half of a century Mitsubishi low voltage circuit breakers meet the needs of market. Including the WS-V series equipped with a new breaking technology, Mitsubishi Low Voltage Circuit Breakers have various lineups depending on the electric power market and the machinery.

Air Circuit Breakers

Make electrical equipment multi-functional by means of Mitsubishi air circuit breakers that are suitable for protection of the main circuit.

Air circuit breakers have many advantages, among them adding higher reliability during switching. They can be used to extend the area of selective coordination trough expansion of the rated short-time withstand current, for use in main circuit ports.

 


Air Circuit Breakers (ACB) AE-SW


Air Circuit Breakers (ACB)

This kind of breaker is used as the main power breaker of the supply such as buildings, factories and ships etc. and satisfy the various needs.

Product Specification:

SUPER AE – WORLD SUPER SERIES

AE1000-SW

AE1250-SW

AE1600-SW

AE2000-SWA

Frame size

A

1000

1250

1600

2000

Rated insulation voltage (AC V) 50/60 Hz

U i

1000

Rated operating voltage (AC V) 50/60 Hz

U e

690

Rated impulse withstand voltage (kV)

U imp

12

Pollution degree

 

3

Number of poles

P

3 / 4

3 / 4

3 / 4

3 / 4

Rated curren t I n (CT rating)

1000

1250

1600

2000

Adjustment range Rated current I r (A)

General use (current rating adjustable

0.5 to 1.0 x I n 0.05 step)

500-550-600-650- 700-750-800-850- 900-950 -1000

625-687.5-750-812.5- 875-937.5-1000-1062.5-1125-1187.5-1250

800-880-960-1040- 1120-1200-1280-1360- 1440-1520-1600

1000-1100-1200-1300- 1400-1500-1600-1700- 1800-1900-2000

Generator protection(current rating fixed)

400 ≤ I r ≤ 1000

800 ≤ I r ≤ 1250

1000 ≤ I r ≤ 1600

1250 ≤ I r ≤ 2000

Rated current of neutral pole

A

1000

1250

1600

2000

IEC 60947-2, EN 60947-2, VDE, JIS C 8201-2-1

Ultimate breaking capacity I cu (kA rms)

 

690 V AC

65

65

65

65

600 V AC

65

65

65

65

240–500 V AC

65

65

65

65

With MCR

690 V AC

65

65

65

65

600 V AC

65

65

65

65

240–500 V AC

65

65

65

65

Withoutinstantaneous

690 V AC

25 a

25 a

25 a

25 a

500 V AC

25 a

25 a

25 a

25 a

Rated service breaking capacity Ics (kA rms) % lcu

 

Rated making capacity I cm (kA, peak)

 

690 V AC

143

143

143

143

 

600 V AC

143

143

143

143

240–500 V AC

143

143

143

143

With MCR

690 V AC

143

143

143

143

600 V AC

143

143

143

143

240–500 V AC

143

143

143

143

Withoutinstantaneous

690 V AC

52.5

52.5

52.5

52.5

500 V AC

52.5

52.5

52.5

52.5

Disconnector: switching capacity (6x I r at 690V AC)

O

O

O

O

Rated short time withstand current (kA rms)  I cw

1 s

65

65

65

65

2 s

60

60

60

60

3 s

50

50

50

50

Maximum total breaking time

ms

40 f

40 f

40 f

40 f

Closing time

ms

80

80

80

80

Number of operating cycles (ON/OFF) b

With ratedcurrent

500 V AC I n

5000

5000

5000

1500

690 V AC I n

5000

5000

5000

1500

Without rated current d

25000

25000

25000

25000

Connecting terminal

Horizontal terminal

O

O

O

Vertical terminal

O

O

O

c

Front terminal

O

O

O

Dimensions (HxWxD) mm

Fixed type

3-pole

410x340x290

4-pole

410x425x290

Drawout type

3-pole

430x300x368

4-pole

430x385x368

Weight kg

Fixed type

3-pole

41

41

42

47

4-pole

51

51

52

57

Drawout type(with cradle)

3-pole

64

64

65

70

4-pole

78

78

79

84

Cradle only

3-pole

26

26

26

31

4-pole

30

30

30

35

 

  1. The columns for “without instantaneous” are the values when the bare main body and the external relay is combined.
  2. The number of operating cycles without rated current also include the number of operating cycles with rated current.
  3. AE4000-SW, AE5000-SW, AE6300-SW, AE2000-SWA and AE4000-SWA apply for only vertical terminal of connecting terminal.
  4. This value means number of operating cycles of ACB's body not including accessories.
  5. Products with low rating types is available.

 

SUPER AE – WORLD SUPER SERIES

AE2000-SW

AE2500-SW

AE3200-SW

AE4000-SWA

AE4000-SW

AE5000-SW

AE6300-SW

Frame size

A

2000

2500

3200

4000

4000

5000

6300

Rated insulation voltage (AC V) 50/60 Hz

U i

1000

1000

Rated operating voltage (AC V) 50/60 Hz

U e

690

690

Rated impulse withstand voltage (kV)

Uimp

12

12

Pollution degree

 

3

3

Number of poles

P

3 / 4

3 / 4

3 / 4

3 / 4

3 / 4(HN, FN) g

3 / 4(HN, FN) g

3 / 4(HN, FN) g

Rated curren t I n (CT rating)

2000

2500

3200

4000

4000

5000

6300

Adjustment range Rated current I r (A)

General use (current rating adjustable

0.5 to 1.0 x I n 0.05 step)

1000-1100-1200-1300- 1400-1500-1600-1700- 1800-1900-2000 e

1250-1375-1500-1625- 1750-1875-2000-2125- 2250-2375-2500

1600-1760-1920-2080- 2240-2400-2560-2720- 2880-3040-3200

2000-2200-2400-2600- 2800-3000-3200-3400- 3600-3800-4000

2000-2200-2400-2600- 2800-3000-3200-3400- 3600-3800-4000

2500-2750-3000-3250- 3500-3750-4000-4250- 4500-4750-5000

3150-3465-3780-4095- 4410-4725-5040-5355- 5670-5985-6300

Generator protection(current rating fixed)

800 ≤ I r ≤ 2000

1600 ≤ I r ≤ 2500

2000 ≤ I r ≤ 3200

2500 ≤ I r ≤ 4000

2500 ≤ I r ≤ 4000

3150 ≤ I r ≤ 5000

4000 ≤ I r ≤ 6300

Rated current of neutral pole

A

2000

2500

3200

4000

2000 (4000) h

2500 (5000) h

3150 (6300) h

IEC 60947-2,EN 60947-2,VDE, JIS C 8201-2-1

Ultimate breaking capacity Icu (kA rms)

 

690 V AC

75

75

75

75

85

85

85

600 V AC

75

75

75

75

85

85

85

240–500 V AC

85

85

85

85

130

130

130

With MCR

690 V AC

75

75

75

75

85

85

85

600 V AC

75

75

75

75

85

85

85

240–500 V AC

75

75

75

75

100

100

100

Withoutinstantaneous

690 V AC

45 a

45 a

45 a

45 a

65 a

65 a

65 a

500 V AC

45 a

45 a

45 a

45 a

65 a

65 a

65 a

Rated service breaking capacity Ics (kA rms) % l cu

100 %

100 %

Rated making capacity Icm (kA, peak)

 

690 V AC

165

165

165

165

187

187

187

 

600 V AC

165

165

165

165

187

187

187

240–500 V AC

187

187

187

187

 286

286

 286

With MCR

690 V AC

165

165

165

165

187

187

187

600 V AC

165

165

165

165

187

187

187

240–500 V AC

165

165

165

165

220

220

220

Withoutinstantaneous

690 V AC

94.5

94.5

94.5

94.5

143

143

143

500 V AC

94.5

94.5

94.5

94.5

143

143

143

Disconnector: switching capacity (6x I r at 690V AC)

O

O

O

O

O

O

O

Rated short time withstand current (kA rms)  I cw

1 s

75

75

75

75

100

100

100

2 s

75

75

75

75

85

85

85

3 s

65

65

65

65

85

85

85

Maximum total breaking time

ms

40 f

40 f

40 f

40 f

50 f

50 f

50 f

Closing time

ms

80

80

80

80

80

80

80

Number of operating cycles(ON/OFF) b

With ratedcurrent

500 V AC In

1500

1500

1000

500

1000

1000

1000

690 V AC In

1500

1500

1000

500

1000

1000

1000

Without rated current d

20000

20000

20000

20000

10000 (3P)/5000 (4P)

10000 (3P)/5000 (4P)

10000 (3P)/5000 (4P)

Connecting terminal

Horizontal terminal

O

O

O

Vertical terminal

O

O

O

c

c

c

c

Front terminal

O

O

O

Dimensions (HxWxD) mm

Fixed type

3-pole

410x475x290

414x873x290

4-pole

410x605x290

414x1003 (1133)x290 h

Drawout type

3-pole

430x435x368

430x439x368

480x875x368

4-pole

430x565x368

430x569x368

480x1005 (1135)x368 h

Weight kg

Fixed type

3-pole

60

61

63

81

160

160

160

4-pole

72

73

75

99

180 (200) h

180 (200) h

180 (200) h

Drawout type(with cradle)

3-pole

92

93

95

108

233

233

240

4-pole

113

114

116

136

256 (279) h

256 (279) h

263 (286) h

Cradle only

3-pole

35

35

35

49

118

118

125

4-pole

43

43

43

61

133 (148) h

133 (148) h

140 (155) h

 

  1. f) This value means the instantaneous breaking time at short-circuit interruption. As for accessories (UVT, SHT)
  2. g) 4 (HN) means the neutral poles current capacity is 50 % of the rated current, for 4-poles.4 (FN) means the neutral poles current capacity is 100 % of the rated current, for 4-poles.
  3. h) () shows the value for 4P FN type.
  4. Remarks:– All models conform the isolating function according to IEC 60947-2.– Reverse connection is possible

Molded Case Circuit Breakers

Wide assortment of products that is highly suitable for protection against overload and short-circuit conditions.

These are basic products for the protection of low voltage circuits. The WS-V series, Mitsubishi's latest series of Low Voltage Circuit Breakers, offers a number of different versions, including "F-style" small size breakers, with improved usability.

 


Molded-Case Circuit Breakers (MCCB) NF


Molded-Case Circuit Breakers (MCCB)

The molded case circuit breaker (MCCB) opens and closes a low voltage circuit, and breaks the fault current (an overload current or short circuit current) automatically, to protect the wirings/conductors of the circuit.

Product Specification:

Type/series

WS-V series

NF32-SV

NF63-SV

NF125-SV

NF125-SGV

NF125-SEV

NF160-SGV

NF250-SV

NF250-SGV

NF250-SEV

S series

Rated current I n max. [A]

32

63

125

125*

125*

160*

250

250*

250*

Rated insulation voltage U i [V]

AC

600

600

690

690

690

690

690

690

690

Number of poles

3

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

Ratedbreakingcapacity[kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2VDE 0660

AC a (50/60 Hz)

690 V

8/8

8/8

8/8

8/8

8/8

8/8

8/8

500 V

2.5/2.5

7.5/7.5

18/18

30/30

30/30

30/30

30/30

30/30

30/30

440 V

2.5/2.5

7.5/7.5

25/25

36/36

36/36

36/36

36/36

36/36

36/36

400 V

5/5

7.5/7.5

30/30

36/36

36/36

36/36

36/36

36/36

36/36

230 V

7.5/7.5

15/15

30/30

85/85

85/85

85/85

85/85

85/85

85/85

Dimensions WxHxD

[mm]

75x130x68

75/100x130x68

90/120/x130x68

105/140x165x68

105/140x165x68

105/140x165x68

105/140x165x68

105/140x165x68

105/140x165x68

 

Type

   

NF125-LGV

   

NF160-LGV

 

NF250-LGV

 

L series

Rated current I n max. [A]

   

125*

   

160*

 

250*

 

Rated insulation voltage U i [V]

AC

   

690

   

690

 

690

 

Number of poles

   

3/4

   

3/4

 

3/4

 

Ratedbreakingcapacity[kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2VDE 0660

AC a (50/60 Hz)

690 V

   

8/8

   

8/8

 

8/8

 

500 V

   

36/36

   

36/36

 

36/36

 

440 V

   

50/50

   

50/50

 

50/50

 

400 V

   

50/50

   

50/50

 

50/50

 

230 V

   

90/90

   

90/90

 

90/90

 

Dimensions WxHxD

[mm]

   

105/140x165x68

   

105/140x165x68

 

105/140x165x68

 
 

Type

 

NF63-HV

NF125-HGV

 

NF125-HEV

NF160-HGV

 

NF250-HGV

NF250-HEV

H series

Rated current I n max. [A]

 

63

125*

 

125*

160*

 

250*

250*

Rated insulation voltage U i [V]

AC

 

690

690

 

690

690

 

690

690

Number of poles

 

3/4

3/4

 

3/4

3/4

 

3/4

3/4

Ratedbreakingcapacity[kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2VDE 0660

AC a (50/60 Hz)

690 V

 

2.5/2.5

10/8

 

10/8

10/8

 

10/8

10/8

500 V

 

7.5/7.5

50/38

 

50/38

50/38

 

50/50

50/50

440 V

 

10/8

65/65

 

65/65

65/65

 

65/65

65/65

400 V

 

10/8

75/75

 

75/75

75/75

 

75/75

75/75

230 V

 

25/19

100/100

 

100/100

100/100

 

100/100

100/100

Dimensions WxHxD

[mm]

 

75/100x130x68

105/140x165x68

 

105/140x165x68

105/140x165x68

 

105/140x165x68

105/140x165x68

 

Type

   

NF125-RGV

       

NF250-RGV

 

R series

Rated current I n max. [A]

   

125*

       

250*

 

Rated insulation voltage U i [V]

AC

   

690

       

690

 

Number of poles

   

3

       

3

 

Ratedbreakingcapacity[kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2VDE 0660

AC a (50/60 Hz)

690 V

   

       

 

500 V

   

       

 

440 V

   

125/125

       

125/125

 

400 V

   

150/150

       

150/150

 

230 V

   

150/150

       

150/150

 

Dimensions WxHxD

[mm]

   

105x165x68

       

105x165x68

 
 

Type

   

NF125-UV

       

NF250-UV

 

U series

Rated current I n max. [A]

   

125

       

250

 

Rated insulation voltage U i [V]

AC

   

690

       

690

 

Number of poles

   

3/4

       

3/4

 

Ratedbreakingcapacity[kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2VDE 0660

AC a (50/60 Hz)

690 V

   

10/10

       

15/15

 

500 V

   

200/200

       

200/200

 

440 V

   

200/200

       

200/200

 

400 V

   

200/200

       

200/200

 

230 V

   

200/200

       

200/200

 

Dimensions WxHxD

[mm]

   

105/140x240x68

       

105/140x240x68

 
 

Type

DSN32-SV

DSN63-SV

DSN125-SGV

   

DSN160-SGV

 

DSN250-SGV

 

Disconnectors

Rated current I n max. [A]

32

63

125

   

160

 

250

 

Rated insulation voltage U i [V]

AC/DC

600

600

690

   

690

 

690

 

Rated voltage U e[V]

AC (50/60 Hz)/DC

500/250

500/250

690/300

   

690/300

 

690/300

 

Number of poles

3

3/4

3/4

   

3/4

 

3/4

 

Max. switching current [A] (breaking)

AC/DC

256/128

504/252

1000/500

   

1280/640

 

2000/1000

 

Dimensions WxHxD

[mm]

75x130x68

75/120x130x68

105/140x165x68

   

105/140x165x68

 

105/140x165x68

 

a DC on request b In case of solderless terminal, interrupting capacity reduces. * adjustable

Type/series

WS series

           

NF400-SEW

NF630-SEW

NF800-SEW

NF1000-SEW

NF1250-SEW

NF1600-SEW

S series

Rated current I n max. [A]

400*

630*

800*

1000*

1250*

1600*

Rated insulation voltage U i [V]

AC

690

690

690

690

690

690

Number of poles

3/4

3/4

3/4

3/4

3/4

3/4

Rated breakingcapacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

10/10 b

10/10

10/10

25/13

25/13

25/13

500 V

30/30 b

30/30

30/30

65/33

65/33

65/33

440 V

42/42 b

42/42

42/42

85/43

85/43

85/43

400 V

50/50 b

50/50

50/50

85/43

85/43

85/43

230 V

85/85 b

85/85

85/85

125/63

125/63

125/63

Dimensions WxHxD

[mm]

140/185x257x103

140/185x257x103

210/280x275x103

210/280x406x140

210/280x406x140

210/280x406x140

 

Type

NF400-HEW

NF630-HEW

NF800-HEW

     

H series

Rated current I n max. [A]

400*

630*

800*

     

Rated insulation voltage U i [V]

AC

690

690

690

     

Number of poles

3/4

3/4

3/4

     

Rated breakingcapacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

10/10

15/15

15/15

     

500 V

50/50

50/50

50/50

     

440 V

65/65

65/65

65/65

     

400 V

70/70

70/70

70/70

     

230 V

100/100

100/100

100/100

     

Dimensions WxHxD

[mm]

140/185x257x103

140/185x257x103

210/280x275x103

     
 

Type

NF400-REW

NF630-REW

NF800-REW

     

R series

Rated current I n max. [A]

400*

630*

800*

     

Rated insulation voltage U i [V]

AC

690

690

690

     

Number of poles

3

3

3

     

Rated breakingcapacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

15/10

20/15

20/15

     

500 V

70/35

70/35

70/35

     

440 V

125/63

125/63

125/63

     

400 V

125/63

125/63

125/63

     

230 V

150/75

150/75

150/75

     

Dimensions WxHxD

[mm]

140x257x103

140x257x103

210x275x103

     
 

Type

NF400-UEW

 

NF800-UEW

     

U series

Rated current I n max. [A]

400*

 

800*

     

Rated insulation voltage U i [V]

AC

690

 

690

     

Number of poles

3/4

 

3/4

     

Rated breakingcapacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

35/35

 

35/35

     

500 V

170/170

 

170/170

     

440 V

200/200

 

200/200

     

400 V

200/200

 

200/200

     

230 V

200/200

 

200/200

     

Dimensions WxHxD

[mm]

140/280x297/322x200

 

210/280x322x200

     
 

Type

DSN400-SW

DSN630-SW

DSN800-SW

DSN1000-SW

DSN1250-SW

DSN1600-SW

Disconnectors

Rated current I n max. [A]

400

630

800

1000

1250

1600

Rated insulation voltage U i [V]

AC/DC

690

690

690

660

660

660

Rated voltage U e [V]

AC (50/60 Hz)/DC

690/250

690/250

690/250

660/250

660/250

660/250

Number of poles

3/4

3/4

3/4

3/4

3/4

3/4

Max. switching current [A] (breaking)

AC/DC

3200/1600

5040/2520

6400/3200

8000/14000

10000/5000

12800/6400

Dimensions WxHxD

[mm]

140/185x257x103

140/185x257x103

210/280x275x103

210/280x406x140

210/280x406x140

210/280x406x140

* adjustable

 

 

Earth Leakage Circuit Breakers

Wide assortment of products that is highly suitable for protection against overload, short-circuit conditions and electric shocks in low voltage circuits.

These are basic products for the protection of low voltage circuits. The WS-V series, Mitsubishi's latest series of Low Voltage Circuit Breakers, offers a number of different versions, including "F-style" small size breakers, with improved usability.

 

 

 


​Earth Leakage Circuit Breakers (ELCB) NV


Earth-Leakage Circuit Breakers (ELCB)

The earth leakage circuit breaker (ELCB) is used to protect persons against electric shock hazards and to prevent a fire. This also have the same function as MCCB.

Product Specification:

Type

BV-DN

NV125-CV

NV250-CV

Rated current I n [A]

 

10, 16, 20, 25, 32, 40

80, 100, 125

150, 175, 200, 225, 250

Number of poles

 

2 (1+N)

3

3

Rated voltage [V AC]

 

230

100–440

100–440

Rated current sensitivity [mA]

 

30

100/200/500 selectable

100/200/500 selectable

Max. operating time [s]

 

0.04

0.45/1.0/2.0 selectable

0.45/1.0/2.0 selectable

Pulsating current sensitivity

 

AC

A (Harmonic Surge Ready)

A (Harmonic Surge Ready)

Rated breaking capacity [kA]

230 V AC

4.5

30

36

440 V AC

10

15

Number of operating cycles

Without current

20000

10000

8000

With current

20000 (In 10, 16,20 A) 15000 (In 25 A) 10000 (In 32, 40 A)

6000

4000

Dimensions [mm]

 

a

36

90

105

b

88

130

165

c

44

68

68

ca

70

90

92

Mass [kg]

 

0.19

1

1.7

Automatic tripping device

 

Thermal-magnetic

Thermal-magnetic

Thermal-magnetic

Based on standard

 

IEC61009-1

IEC60947-2

IEC60947-2

Breaker type

 

MCB

MCCB

MCCB

CE marking

 

Self-declaration

Self-declaration

TÜV approval

 

Type

2P (1P+N)

3P

RCBO (Residual current circuit breakers with overcurrent protection)

BV-DN 1PN 10A 30MA N

248280

BV-DN 1PN 16A 30MA N

248283

BV-DN 1PN 20A 30MA N

248286

BV-DN 1PN 25A 30MA N

248289

BV-DN 1PN 32A 30MA N

248292

BV-DN 1PN 10A 40MA N

248295

ELCB (Earth leakage circuit breakers)

NV125-CV 3P 80A 2-440V 1.2.500MA JIEN CE

265624

NV125-CV 3P 100A 2-440V 1.2.500MA JIEN CE

265625

NV125-CV 3P 125A 2-440V 1.2.500MA JIEN CE

265626

NV250-CV 3P 150A 2-440V 1.2.500MA JIEN CE

265792

NV250-CV 3P 175A 2-440V 1.2.500MA JIEN CE

265793

NV250-CV 3P 200A 2-440V 1.2.500MA JIEN CE

265794

NV250-CV 3P 225A 2-440V 1.2.500MA JIEN CE

265795

NV250-CV 3P 250A 2-440V 1.2.500MA JIEN CE

265796

Miniature Circuit Breakers

Miniature Circuit Breakers (MCBs) are compact electro-mechanical devices for up to 63A, for protection against overload and short-circuit conditions.

Mainly used for household applications and similar.

 


Miniature Circuit Breakers (MCB) BH-D, BH-DN


Miniature Circuit Breakers (MCB)

Standard: IEC60898-1
Breaking capacity:
4.5kA to 10kA 230/400VAC,
10kA 250VDC.

Product Specification:

Miniature circuit breakers (MCB)

Type

BHW-T10

Miniature circuit breakers (MCB)

No. of poles P

1

2

3

4

1

2

3

4

Instantaneous tripping

Type B

Type C, D 1

Rated insulation voltage U i [V]

660

660

Rated c urrent I n [A] at ambient temperature 30° C

6, 10, 16, 20, 25, 32, 40, 50, 63

0.5, 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 62

Rated short-circuit capacity [kA]

IEC/EN 60898-1 (Icn)

AC

240 V

10

10

240 V/ 415 V

10

10

415 V

10

10

Energy limiting class 2

 

Number of operating cycles

Without current

 

With current

 

Type of overcurrent release

Thermal-magnetic

Mounting

IEC 35 mm rail

Applicable wire size

1 to 25 mm²

Mass [kg]

0.13

0.26

0.39

0.52

0.13

0.26

0.39

0.52

Accessories (optional) 3

Auxiliary switch (AX)

o

Terminal connection

Solderless

Based on Standard

IEC/EN 60898-1

CE marking

o

  1. Type C: (5 In <, 10 In), Type D: (10 In <, 20 In)

  2. Except for type D

  3. Available soon

 


Residual Current Circuit Breakers (RCCB) BV-D


Residual Current Circuit Breakers (RCCB)

Standard: IEC61008
Type of residual current: Type AC

Product Specification:

Residual current breakers (RCCB)

Type

BVW-T

No. of poles P

2 (1+N) 1

4 (3+N) 1

Rated c urrent I n [A] at ambient temperature 30° C

25, 40, 63

Rated voltage [V AC]

240

415

Rated current sensitivity I g n [mA]

30, 300

Max. operating time at I g n [s]

0.04

Pulsating current sensitivity

Type AC

Rated making and breaking capacity I m [A]

500 (In 25, 40 A), 630 (In 63 A)

Rated conditional short-circuit current I nc [kA]

5

Rated residual making and breaking capacity I g m [A]

500 (In 25, 40 A), 630 (In 63 A)

Rated conditional residual short-circuit current I g C [kA]

6

Number of o perating cycles

Without current

4,000 2

With current

2,000

Type of overcurrent release

Mounting

IEC 35 mm rail

Applicable wire size

1 to 25 mm²

Mass [kg]

0.22

0.44

Terminal connection

Solderless

Based on standard

IEC/EN 61008-1

CE marking

o

1 N pole is a switched neutral pole (without overcurrent release device).

Residual current breakers (RCCB)

 


Residual Current Circuit Breakers with Overload Protection (RCBO) BV-DN


Residual Current Circuit Breakers with Overload Protection (RCBO) BV-DN

Standard: IEC61009
Breaking capacity:
4.5kA 230VAC
Type of residual current: Type AC

Product Specification:

Type

BV-DN

NV125-CV

NV250-CV

Rated current I n [A]

 

10, 16, 20, 25, 32, 40

80, 100, 125

150, 175, 200, 225, 250

Number of poles

 

2 (1+N)

3

3

Rated voltage [V AC]

 

230

100–440

100–440

Rated current sensitivity [mA]

 

30

100/200/500 selectable

100/200/500 selectable

Max. operating time [s]

 

0.04

0.45/1.0/2.0 selectable

0.45/1.0/2.0 selectable

Pulsating current sensitivity

 

AC

A (Harmonic Surge Ready)

A (Harmonic Surge Ready)

Rated breaking capacity [kA]

230 V AC

4.5

30

36

440 V AC

10

15

Number of operating cycles

Without current

20000

10000

8000

With current

20000 (In 10, 16,20 A) 15000 (In 25 A) 10000 (In 32, 40 A)

6000

4000

Dimensions [mm]

 

a

36

90

105

b

88

130

165

c

44

68

68

ca

70

90

92

Mass [kg]

 

0.19

1

1.7

Automatic tripping device

 

Thermal-magnetic

Thermal-magnetic

Thermal-magnetic

Based on standard

 

IEC61009-1

IEC60947-2

IEC60947-2

Breaker type

 

MCB

MCCB

MCCB

CE marking

 

Self-declaration

Self-declaration

TÜV approval

 

Type

2P (1P+N)

3P

RCBO (Residual current circuit breakers with overcurrent protection)

BV-DN 1PN 10A 30MA N

248280

BV-DN 1PN 16A 30MA N

248283

BV-DN 1PN 20A 30MA N

248286

BV-DN 1PN 25A 30MA N

248289

BV-DN 1PN 32A 30MA N

248292

BV-DN 1PN 10A 40MA N

248295

ELCB (Earth leakage circuit breakers)

NV125-CV 3P 80A 2-440V 1.2.500MA JIEN CE

265624

NV125-CV 3P 100A 2-440V 1.2.500MA JIEN CE

265625

NV125-CV 3P 125A 2-440V 1.2.500MA JIEN CE

265626

NV250-CV 3P 150A 2-440V 1.2.500MA JIEN CE

265792

NV250-CV 3P 175A 2-440V 1.2.500MA JIEN CE

265793

NV250-CV 3P 200A 2-440V 1.2.500MA JIEN CE

265794

NV250-CV 3P 225A 2-440V 1.2.500MA JIEN CE

265795

NV250-CV 3P 250A 2-440V 1.2.500MA JIEN CE

265796

Miniature Circuit Breakers

Miniature Circuit Breakers (MCBs) are compact electro-mechanical devices for up to 63A, for protection against overload and short-circuit conditions.

Mainly used for household applications and similar.

 

 


Miniature Circuit Breakers (MCB) BH-D, BH-DN


Miniature Circuit Breakers (MCB)

Standard: IEC60898-1
Breaking capacity:
4.5kA to 10kA 230/400VAC,
10kA 250VDC.

Product Specification:

Miniature circuit breakers (MCB)

Type

BHW-T10

Miniature circuit breakers (MCB)

No. of poles P

1

2

3

4

1

2

3

4

Instantaneous tripping

Type B

Type C, D 1

Rated insulation voltage U i [V]

660

660

Rated c urrent I n [A] at ambient temperature 30° C

6, 10, 16, 20, 25, 32, 40, 50, 63

0.5, 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 62

Rated short-circuit capacity [kA]

IEC/EN 60898-1 (Icn)

AC

240 V

10

10

240 V/ 415 V

10

10

415 V

10

10

Energy limiting class 2

 

Number of operating cycles

Without current

 

With current

 

Type of overcurrent release

Thermal-magnetic

Mounting

IEC 35 mm rail

Applicable wire size

1 to 25 mm²

Mass [kg]

0.13

0.26

0.39

0.52

0.13

0.26

0.39

0.52

Accessories (optional) 3

Auxiliary switch (AX)

o

Terminal connection

Solderless

Based on Standard

IEC/EN 60898-1

CE marking

o

 

  1. Type C: (5 In <, 10 In), Type D: (10 In <, 20 In)
  2. Except for type D
  3. Available soon

 


Residual Current Circuit Breakers (RCCB) BV-D


Residual Current Circuit Breakers (RCCB)

Standard: IEC61008
Type of residual current: Type AC

Product Specification:

Residual current breakers (RCCB)

Type

BVW-T

No. of poles P

2 (1+N) 1

4 (3+N) 1

Rated c urrent I n [A] at ambient temperature 30° C

25, 40, 63

Rated voltage [V AC]

240

415

Rated current sensitivity I g n [mA]

30, 300

Max. operating time at I g n [s]

0.04

Pulsating current sensitivity

Type AC

Rated making and breaking capacity I m [A]

500 (In 25, 40 A), 630 (In 63 A)

Rated conditional short-circuit current I nc [kA]

5

Rated residual making and breaking capacity I g m [A]

500 (In 25, 40 A), 630 (In 63 A)

Rated conditional residual short-circuit current I g C [kA]

6

Number of o perating cycles

Without current

4,000 2

With current

2,000

Type of overcurrent release

Mounting

IEC 35 mm rail

Applicable wire size

1 to 25 mm²

Mass [kg]

0.22

0.44

Terminal connection

Solderless

Based on standard

IEC/EN 61008-1

CE marking

o

1 N pole is a switched neutral pole (without overcurrent release device).

Residual current breakers (RCCB)

 


Residual Current Circuit Breakers with Overload Protection (RCBO) BV-DN


Residual Current Circuit Breakers with Overload Protection (RCBO) BV-DN

Standard: IEC61009
Breaking capacity:
4.5kA 230VAC
Type of residual current: Type AC

Product Specification:

Type

BV-DN

NV125-CV

NV250-CV

Rated current I n [A]

 

10, 16, 20, 25, 32, 40

80, 100, 125

150, 175, 200, 225, 250

Number of poles

 

2 (1+N)

3

3

Rated voltage [V AC]

 

230

100–440

100–440

Rated current sensitivity [mA]

 

30

100/200/500 selectable

100/200/500 selectable

Max. operating time [s]

 

0.04

0.45/1.0/2.0 selectable

0.45/1.0/2.0 selectable

Pulsating current sensitivity

 

AC

A (Harmonic Surge Ready)

A (Harmonic Surge Ready)

Rated breaking capacity [kA]

230 V AC

4.5

30

36

440 V AC

10

15

Number of operating cycles

Without current

20000

10000

8000

With current

20000 (In 10, 16,20 A) 15000 (In 25 A) 10000 (In 32, 40 A)

6000

4000

Dimensions [mm]

 

a

36

90

105

b

88

130

165

c

44

68

68

ca

70

90

92

Mass [kg]

 

0.19

1

1.7

Automatic tripping device

 

Thermal-magnetic

Thermal-magnetic

Thermal-magnetic

Based on standard

 

IEC61009-1

IEC60947-2

IEC60947-2

Breaker type

 

MCB

MCCB

MCCB

CE marking

 

Self-declaration

Self-declaration

TÜV approval

 

Type

2P (1P+N)

3P

RCBO (Residual current circuit breakers with overcurrent protection)

BV-DN 1PN 10A 30MA N

248280

BV-DN 1PN 16A 30MA N

248283

BV-DN 1PN 20A 30MA N

248286

BV-DN 1PN 25A 30MA N

248289

BV-DN 1PN 32A 30MA N

248292

BV-DN 1PN 10A 40MA N

248295

ELCB (Earth leakage circuit breakers)

NV125-CV 3P 80A 2-440V 1.2.500MA JIEN CE

265624

NV125-CV 3P 100A 2-440V 1.2.500MA JIEN CE

265625

NV125-CV 3P 125A 2-440V 1.2.500MA JIEN CE

265626

NV250-CV 3P 150A 2-440V 1.2.500MA JIEN CE

265792

NV250-CV 3P 175A 2-440V 1.2.500MA JIEN CE

265793

NV250-CV 3P 200A 2-440V 1.2.500MA JIEN CE

265794

NV250-CV 3P 225A 2-440V 1.2.500MA JIEN CE

265795

NV250-CV 3P 250A 2-440V 1.2.500MA JIEN CE

265796

UL 489 Listed Circuit Breakers

The best choice for overcurrent protection in North American countries.

These breakers comply with the American UL standard and the Canadian CSA standard, and are listed by UL. They are suitable for use with feeders and for branch circuit protection.

 

 

 


UL 489 Listed Molded Case Circuit Breakers NF-U


UL 489 Listed Molded Case Circuit Breakers

This kind of breaker complies to UL 489 and CSA C22.1No.5.

Product Specification:

Type

NF125-UV

NF250-UV

NF400-UEW

NF800-UEW

Rated data

Rated current I n [A] at ambient temperature

40 °C

15, 20, 30, 40, 50, 60, 75, 100, 125 Fixed

125, 150, 175, 200, 225, 250 Fixed

200–400Adjustable

500–1000Adjustable

Number of poles

3/4

3/4

3/4

3/4

Rated insulation voltage U i [V]

AC

690

690

690

690

Rated breaking capacity [kA] ( I cu / I cs )

IEC/EN 60947-2

AC (50/60 Hz)

690 V

10/10

15/15

35/35

25/13

500 V

200/200

200/200

170/170

65/33

440 V

200/200

200/200

200/200

85/43

400 V

200/200

200/200

200/200

85/43

230 V

200/200

200/200

200/200

125/63

DC

250 V

B

B

Utilization category

A

A

5/0.25

20/0.3

Rated impulse withstand voltage U imp [kV]

8

8

8

8

Pollution degree

3

3

3

3

Reverse connection

O

O

O

O

Suitable for isolation

O

O

O

O

Mechanical data

Dimensions [mm]

a

90/120

105/140

140/280

210/280

b

191

240

297/322

406

c

68

68

200

140

ca

92

92

252

190

Weight [kg]

1.5/1.9

2.7/3.7

16.7/26.1

23.5/30.7

Cassette- type accessories

Alarm switch

(AL)

O

O

O

O

Auxiliary switch

(AX)

O

O

O

O

Shunt trip

(SHT)

O

O

O

O

Undervoltage trip

Non-synchronous closing

(UVT-N)

O

O

O

Synchronous closing

(UVT-S)

O

O

O

Accessories connection

With terminal block

(SLT)

O

O

O

O

With internal terminal type

O

O

O

O

Installation and connection

Front

Screw terminal (standard)

O

O

O

O

Solderless terminal

O

O

O

Busbar terminal

O /—

Rear

(B)

O

O

O

O

Plug-in

Rear

(PM)

—/ O

O

O

Rear front IP 20 with auto trip

(PM-IP)

O /—

O /—

O

Built-in accessories

Pre-alarm-contact output a

(PAL)

O

Overcurrent trip alarm a

(OAL)

O

External accessories

External operating handle

Door mounting

(V)

O

O

O

O

Mounted on breaker

(R)

O

O

O

Electrical operation device

(MDS)

O

O

O

O

Handle lock device

Handle lock for use with padlock

(HL)

O

O

O

(HL-S)

O

O

O

O

Lock cover

(LC)

O

O

O

O

Terminal cover

Large

(TC-L)

O

O

LR, GL, BV, AB

LR, GL, AB

Small

(TC-S)

O

O

Electronic

Electronic

For rear connection

(BTC)

O

O

Equipped

Equipped

For plug-in

(PTC)

O

O

O

O

Mechanical interlock

(MI)

O

O

O

O

Insulating barrier

Between phases (Standard)

(BA-F)

O

O

O

O

Adapter for IEC 35 mm rail

O /—

O

Others

CE marking

Self-declaration

Self-declaration

Self-declaration

Self-declaration

CCC recognition

Recognized

Recognized

Automatic tripping device

Thermal-magnetic

Thermal-magnetic

Thermal-magnetic

Thermal-magnetic

Trip button

Equipped

Equipped

Equipped

Equipped

 

 


UL 489 Listed Molded Case Circuit Breakers with Ground Fault Protection NV-U


UL 489 Listed Molded Case Circuit Breakers with Ground Fault Protection

This kind of breaker complies to UL 1053 and CSA C22.1No.144.

 

Circuit Breakers for Use in Particular Applications

Upgrade your electrical equipment by using products suitable for your particular application.

If it is considered as proper when the standard MCCB/ELCB is not chosen to use in a special characteristic of the load, the special breaker is needed.

 


Isolation Switches DSN


Isolation Switches

On creating an isolation switch (DSN) by omitting the overcurrent tripping device of a MCCB, it can be used as a switching device with high operating capacity.

Product Specification:

  • WS-V series

Type

DSN32-SV

DSN63-SV

DSN125-SGV

DSN160-SGV

DSN250-SGV

Disconnectors

Rated current I n max. [A]

32

63

125

160

250

Rated insulation voltage U i [V]

AC/DC

600

600

690

690

690

Rated voltage U e [V]

AC (50/60 Hz)/DC

500/250

500/250

690/300

690/300

690/300

Number of poles

3

3/4

3/4

3/4

3/4

Max. switching current [A] (breaking)

AC/DC

256/128

504/252

1000/500

1280/640

2000/1000

Dimensions WxHxD

[mm]

75x130x68

75/120x130x68

105/140x165x68

105/140x165x68

105/140x165x68

 


  • WS series

Type

DSN400-SW

DSN630-SW

DSN800-SW

DSN1000-SW

DSN1250-SW

DSN1600-SW

Disconnectors

Rated current I n max. [A]

400

630

800

1000

1250

1600

Rated insulation voltage U i [V]

AC/DC

690

690

690

660

660

660

Rated voltage U e [V]

AC (50/60 Hz)/DC

690/250

690/250

690/250

660/250

660/250

660/250

Number of poles

3/4

3/4

3/4

3/4

3/4

3/4

Max. switching current [A] (breaking)

AC/DC

3200/1600

5040/2520

6400/3200

8000/14000

10000/5000

12800/6400

Dimensions WxHxD

[mm]

140/185x257x103

140/185x257x103

210/280x275x103

210/280x406x140

210/280x406x140

210/280x406x140

Accessories and Related Components

Suitable for extending circuit breaker functions.

There are many different internal and external accessories. They can be used to make breakers safe and convenient.

 


Internal Accessories AL, AX, SHT, UVT


Internal Accessories

These accessories are installed inside the breaker. AX indicates electrically the status of the breaker. AL indicates electrically the status of the breaker trip. SHT makes the breaker trip electrically by remote operation. UVT releases the breaker when the control voltage is dropped.

Product Specification:

  • Switching operation

Main MCCB conditions

Alarm contacts

OFF or ON

ALa 98 (open) ALc 95 (DC+) a ALb 96 (closed)

Trip

ALa 98 (closed) ALc 95 (DC+) a ALb 96 (open)

  • When DC use, polarity must be considered.

Type of Micro-switch for

Voltage (V AC)

Resistive loads (A)

Inductive load (A)

Voltage (V DC) a

Resistive loads (A)

Inductive load (A)

AL/AX/ALAX-05–8

460

250

0.2

0.2

250

3

2

125

0.4

0.4

125

5

3

30

4

3

AL/AX/ALAX-10

460

5

2

250

0.3

0.3

250

10

10

125

0.6

0.6

125

10

10

30

10

6

  • When DC use, polarity must be considered.

MCCB type a

Cut-off switch

Voltage (V) b

Input c

Operating time(msec) d

AC (VA)

DC (W)

NF32-SV NF63-SV NF63-HV

Equipped

AC 24–48 AC 100–240 AC 380–550 (50/60 Hz) DC 100–125

120

50

≤15

NF125-SGV/SEV NF125-HGV/HEV NF125-RGV/UGV

NF160-SGV/SEV NF160-HGV/HEV

NF250-SGV/SEV NF250-HGV/HEV NF250-RGV/UGV

Equipped

60

NF400-SEW/HEW/REW/UEW NF630-SEW/HEW/REW NF800-CEW/SEW/HEW/REW/UEW

Equipped

AC 24–48/DC 24–48 AC 100–450/DC 100–200 AC 380–550 (50/60 Hz)

100 V: 20 200 V: 50 330 V: 120450 V: 170

100 V: 10 200 V: 35

5–15

NF1000-SEW NF1250-SEW NF1600-SEW

Equipped

AC 100–120 AC 200–240 AC 380–450 (50/60Hz) DC 100

200

70

7–15

  • Also for DSN types.

Main MCCB conditions

Auxiliary contacts

OFF or Trip

AXa 14 (open)

AXc 11 (DC+) a

AXb 12 (closed)

ON

AXa 14 (closed)

AXc 11 (DC+) a

AXb 12 (open)

 


External Accessories Handle, TC, HL, MD


External Accessories

These accessories are mounted outside the breaker. An accessory operates electrically the breaker handle, or the external handle on the panel can be used for breaker operation.

Product Specification:

  • V-type operation handles

 

V-05SV

V-05SVE

V-1SV

V-1SVE

V-2SV

V-2SVE

V-2UV

V-2UVE

V-4S

V-4SE

V-8S

V-8SE

Breaker type

NF/DSN32-63

NF125-SV

NF/DSN125-250-SGV/SEV

NF/DSN125-250-UV

NF/DSN400-630

NF/DSN800

Colour: handle/front

black

red/yellow

black

red/yellow

black

red/yellow

black

red/yellow

black

red/yellow

black

red/yellow

Order information Art. no.

267747

267749

267751

267753

267755

267756

267757

267758

225420

225421

225424

225425

  • Adjustment unit

 

V-AD3S

V-AD5S

V-AD3L

V-AD5L

Breaker type

NF/DSN32-250

NF/DSN400-800

Approx. length (mm)

300

500

300

500

Order information Art. no.

225426

235194

225427

235235

 


Breaker Testers


Breaker Testers

For the WS-V series electronic type breakers, 125 to 250A frame, this device can used to perform release tests, as well as for monitoring and set-up of operating characteristics.